  "boardSha256": "cffc937c4ef9a99235d404857bc63240f49aa6c78caabf841b0965e0e3b028ef",
  "reviewed": "2026-11-11",
  "qualification": "0.0.13 routing/header revision; all original footprints and pad nets unchanged, including corrected USB, socket and reader. Fresh supplier placement/DFM review required.",
  "corrections": {
    "J301": {
      "lcsc": "C5246813",
      "native": [
        46.51,
        8.99,
        180
      ],
      "delta": [
        0,
        0.84,
        180
      ],
      "expected": [
        46.51,
        9.83,
        0
      ],
      "basis": "GCT manufacturer stake pattern and JLC catalog a636b18807724d12b57aad37ab127677 shell-slot centers; preview confirms outward cable mouth, four stakes and solder-tail overlap. Use mechanical stakes as datum, not catalog copper-pad centroids."
    },
    "J601": {
      "lcsc": "C5417011",
      "native": [
        89.42,
        20.05,
        180
      ],
      "delta": [
        -0.8,
        0,
        180
      ],
      "expected": [
        88.62,
        20.05,
        0
      ],
      "basis": "All ten numbered catalog pads and both locating holes match native component-local coordinates after +0.8mm X translation. Bottom-view X reflection makes the CPL origin correction -0.8mm. Catalog fac09934403f4310b3853998f3c08281."
    },
    "U601": {
      "lcsc": "C633309",
      "native": [
        85,
        60.7,
        180
      ],
      "delta": [
        0,
        0,
        180
      ],
      "expected": [
        85,
        60.7,
        0
      ],
      "basis": "Catalog f2fbfd87e0e64900805e04b89a8ad51e pin 1 is upper left in component-side view. Corrected preview pin-1 dot agrees with native triangle; previous raw export placed it lower right."
    }
  },
  "unchangedPolarizedChecks": {
    "D302": "C2297 catalog pad 1 is on the right at zero rotation, unlike the native local pad-1 baseline; existing exported 0deg gives the correct bottom-view cathode orientation. No blanket bottom-side rotation rule applied.",
    "U701": "Top-side regulator orientation unchanged; pin 1 lower left agrees with its native footprint.",
    "D301": "Bidirectional TVS; no polarity-dependent 180deg change required."
  },
  "uploadedCsvPreviewChecked": false,
  "previousBoardSha256": "5a874247461a4dcaff97fbb4b9023068d565e46f8a7cc002c987ccaeaaf6ab08",
  "reviewStatus": "review_required",
  "historicalPreview": "manufacturing/history/0.0.7-preview/",
  "serviceCompatibility": {
    "audit": "angle-header-audit.json",
    "auditSha256": "11fbb4db9362f8216c916a1c3fe63a14d0f012e0b9d805dd11ded7ab223da4fd"
  },
  "ili9341Socket": {
    "audit": "ili9341-socket-audit.json",
    "auditSha256": "31c4096163c8b9443cd22a729ed722389dca10d2ee2c9399ab5962fb716e506b"
  }
}